TA6000

Integrated system

TA6000.

Battery and inverter in one cabinet, with PV input connectivity and three specified storage configurations. AC output options depend on the selected configuration.

INVERTER
Included
ENCLOSURE
Not specified
NOMINAL ENERGY
10.24–20.48 kWh
AC CONFIGURATION
120 V US / 230 V EU AC options
Start your project ↗

Specifications

Model / configurationEnergy (kWh)AC options (kW)
TA6000-M210.246–10
TA6000-M315.366–12
TA6000-M420.486–12

Specify the correct market AC voltage and 50 / 60 Hz option. PV input: 11 kW for M2; 11–13.2 kW for M3/M4. No three-phase or split-phase capability is claimed.

ModelDimensions (mm)Approx. kg
TA6000-M2590 × 570 × 1880 / W × D × H244
TA6000-M3590 × 570 × 1880 / W × D × H286
TA6000-M4590 × 570 × 1880 / W × D × H328

Communication: RS485 / RS232 / CAN / Wi-Fi; Bluetooth optional
Temperature: Operating −20 to 60 °C

Household essentials, planned for a dry dedicated equipment space.

Uganda’s rainfall patterns differ by region, with much of the country having two main rainy seasons and additional mid-year rainfall in northern and some eastern areas. Choose useful storage around your home’s tasks and a protected utility space, rather than a single national installation assumption.

Temperature:
Operating −20 to 60 °C
ENCLOSURE
Not specified
01

Connected household and home-office essentials

A home-office plan can start with lighting, the router and computing equipment, then add refrigeration or other selected household circuits. A dedicated dry utility room keeps the equipment accessible for service.

EU combines battery and inverter in one system for an indoor IP21 installation. Where an appropriate inverter already exists, a TR Pro 51.2 V battery offers a compact battery-only route with confirmed electrical and communication compatibility.

Which appliances should continue running, and for how many hours?
  • Is this a new complete system or an extension of an existing inverter?
02

Rain-season planning in a sheltered service area

Different rainfall seasons make the actual doorway, wall and floor exposure useful details in the inquiry. A dry service room supports an orderly installation away from household activity and water storage.

Choose the enclosure for the real position. TR Pro and HP Ultra list IP66; EU lists IP21, and standard TR/HP K offer different enclosure options. Plan shelter, fixing, drainage and protected cable routes for the exact model.

Can rain, wash water, a roof leak or standing water reach this equipment?
  • Will the installation and its service access remain dry throughout local rainy periods?
03

More energy with a compatible existing inverter

A household that already has a suitable inverter can plan a larger energy reserve around refrigeration, connectivity and chosen circuits, with capacity selected for the desired duration.

Compare compact low-voltage storage with modular high-voltage storage as distinct options. TR Pro is 51.2 V; HP Ultra requires a compatible high-voltage inverter. Check communication and current limits before choosing capacity or module count.

What are the inverter make, model and supported battery-voltage window?
  • Which running and starting loads should the complete system support?
Specifications
  • Plan stored energy in kWh against the required duration and average load. Check inverter AC output, battery limits and motor/compressor starting demand separately before assigning the final essential circuits.
  • Use the exact battery’s environmental limits. TR Pro lists charging at 0 to 55 °C and discharging at −20 to 60 °C; EU lists charging at 0 to 55 °C and discharging at −20 to 55 °C. HP Ultra needs configuration-specific temperature confirmation.
  • Treat enclosure and shelter together: an IP66 rating does not establish flood, condensation or corrosion suitability. TR standard and HP K list IP20 with IP54 optional, TB rack lists IP20, and EU lists IP21; keep their installation conditions distinct.

PRODUCT DETAIL / ORIGINAL LITERATURE

Every side. Every connection.

The supplied brochure provides two labelled connection/breaker insets and internal cabinet/cell illustrations on printed pages 15-16. Crops avoid visible product logos without AI editing, repainting, or invented structure. Embedded views not visibly matched to the printed product page were excluded. These views do not establish pinouts, cable sizes, commissioning steps or installation compatibility.

Original terminal labels
Original terminal labelsConnection panel labelled for load, grid, optional generator, PV and communication.
Terminal panel close-up
Terminal panel close-upClose-up of the cabinet terminal panel.
Original breaker labels
Original breaker labelsBattery, PV1, PV2, load and grid breakers in the illustrated compartment.
Breaker compartment close-up
Breaker compartment close-upCircuit breakers within the cabinet's breaker compartment.
Upper cabinet and service bay
Upper cabinet and service bayUpper cabinet compartment with the inverter and connection area.
Cell assembly detail
Cell assembly detailBattery cell tops in a partial internal illustration.

Know your interfaces.

Power connections

Load Output
Output position identified as Load Output in the brochure.
Grid Input
Connection position identified as Grid Input.
Generator Input (optional)
The generator input is explicitly marked optional in the original callout.
PV Input
PV connection area identified by the original callout.
PV1 Input Breaker
Breaker identified for PV1 Input.
PV2 Input Breaker
Breaker identified for PV2 Input.

Communication

Communication Port
Connection area labelled Communication Port. No protocol pin assignments are specified in this component view.

Controls & indicators

Battery Breaker
Breaker labelled for the battery section.
Load Breaker
Breaker identified for the load connection.
Grid Breaker
Breaker identified for the grid connection.

Source: Residential ESS brochure · PDF page 8 · printed pages 15-16