Low-voltage battery

# TR standard.

Five specified capacities in a wall-mounted LFP battery format. Select the capacity, enclosure and a compatible external inverter for the installation.

INVERTER  Compatible external inverter required

ENCLOSURE  IP20; IP54 optional

NOMINAL ENERGY  5.12–20.07 kWh

BATTERY VOLTAGE  51.2 V nominal DC

[Start your project ↗](https://ug.elvorka.com/en/#enquiry)

## Specifications

| Model / configuration | Energy (kWh) | Nominal DC (V) |
| --- | --- | --- |
| TR4000WX | 5.12 | 51.2 |
| TR6000WX | 10.24 | 51.2 |
| TR8000WX | 14.336 | 51.2 |
| TR8500WX | 16.076 | 51.2 |
| TR10000WX | 20.07 | 51.2 |

Self-heating is optional. Confirm the charge/discharge current, output power and enclosure option for the exact model and inverter.

| Model | Dimensions (mm) | Approx. kg |
| --- | --- | --- |
| TR4000WX | 400 × 750 × 160 / W × H × D | 53.5 |
| TR6000WX | 600 × 750 × 160 / W × H × D | 95 |
| TR8000WX | 480 × 822 × 245 / W × H × D | 110 |
| TR8500WX | 480 × 822 × 245 / W × H × D | 115 |
| TR10000WX | 500 × 922 × 265 / W × H × D | 145 |

Communication: RS485 / RS232 / CAN; Wi-Fi / Bluetooth
Temperature: Charge 0 to 55 °C

## Household essentials, planned for a dry dedicated equipment space.

Uganda’s rainfall patterns differ by region, with much of the country having two main rainy seasons and additional mid-year rainfall in northern and some eastern areas. Choose useful storage around your home’s tasks and a protected utility space, rather than a single national installation assumption.

Temperature:  Charge 0 to 55 °C

ENCLOSURE  IP20; IP54 optional

01

### Connected household and home-office essentials

A home-office plan can start with lighting, the router and computing equipment, then add refrigeration or other selected household circuits. A dedicated dry utility room keeps the equipment accessible for service.

EU combines battery and inverter in one system for an indoor IP21 installation. Where an appropriate inverter already exists, a TR Pro 51.2 V battery offers a compact battery-only route with confirmed electrical and communication compatibility.

Which appliances should continue running, and for how many hours?

- Is this a new complete system or an extension of an existing inverter?

02

### Rain-season planning in a sheltered service area

Different rainfall seasons make the actual doorway, wall and floor exposure useful details in the inquiry. A dry service room supports an orderly installation away from household activity and water storage.

Choose the enclosure for the real position. TR Pro and HP Ultra list IP66; EU lists IP21, and standard TR/HP K offer different enclosure options. Plan shelter, fixing, drainage and protected cable routes for the exact model.

Can rain, wash water, a roof leak or standing water reach this equipment?

- Will the installation and its service access remain dry throughout local rainy periods?

03

### More energy with a compatible existing inverter

A household that already has a suitable inverter can plan a larger energy reserve around refrigeration, connectivity and chosen circuits, with capacity selected for the desired duration.

Compare compact low-voltage storage with modular high-voltage storage as distinct options. TR Pro is 51.2 V; HP Ultra requires a compatible high-voltage inverter. Check communication and current limits before choosing capacity or module count.

What are the inverter make, model and supported battery-voltage window?

- Which running and starting loads should the complete system support?

Specifications

- Plan stored energy in kWh against the required duration and average load. Check inverter AC output, battery limits and motor/compressor starting demand separately before assigning the final essential circuits.

- Use the exact battery’s environmental limits. TR Pro lists charging at 0 to 55 °C and discharging at −20 to 60 °C; EU lists charging at 0 to 55 °C and discharging at −20 to 55 °C. HP Ultra needs configuration-specific temperature confirmation.

- Treat enclosure and shelter together: an IP66 rating does not establish flood, condensation or corrosion suitability. TR standard and HP K list IP20 with IP54 optional, TB rack lists IP20, and EU lists IP21; keep their installation conditions distinct.

PRODUCT DETAIL / ORIGINAL LITERATURE

## Every side. Every connection.

Five model names provide family context, but the compact callout housing is not individually assigned to a SKU. The roller annotation expressly names TR8000WX and TR8500WX. Native photo detail is limited; no replacement surface or port detail is synthesized.

[![Front controls and side terminals](https://ug.elvorka.com/assets/product-details/tr-standard-controls-annotated.png)](https://ug.elvorka.com/assets/product-details/tr-standard-controls-annotated.png)

Front controls and side terminals  Touch screen, status indicators, communication ports and DC terminals on the illustrated cabinet.

[![Rear bracket and terminal-side labels](https://ug.elvorka.com/assets/product-details/tr-standard-rear-bracket-annotated.png)](https://ug.elvorka.com/assets/product-details/tr-standard-rear-bracket-annotated.png)

Rear bracket and terminal-side labels  Rear mounting bracket and side terminal area of the illustrated battery.

[![Circuit control switch detail](https://ug.elvorka.com/assets/product-details/tr-standard-switch-closeup.png)](https://ug.elvorka.com/assets/product-details/tr-standard-switch-closeup.png)

Circuit control switch detail  Circuit control switch with ON/OFF markings.

[![Original rear three-quarter view](https://ug.elvorka.com/assets/product-details/tr-standard-rear-threequarter.png)](https://ug.elvorka.com/assets/product-details/tr-standard-rear-threequarter.png)

Original rear three-quarter view  Rear three-quarter view showing the mounting bracket and terminal side.

[![Original side profile](https://ug.elvorka.com/assets/product-details/tr-standard-side-profile.png)](https://ug.elvorka.com/assets/product-details/tr-standard-side-profile.png)

Original side profile  Side profile showing communication ports and the recessed handle.

### Know your interfaces.

#### Power connections

Negative battery terminal  Negative DC battery power terminal as identified by the original arrow.

Positive battery terminal  Positive DC battery power terminal as identified by the original arrow.

#### Communication

Wi-Fi / Bluetooth  Wi-Fi/Bluetooth feature identified in the callout; no app or pairing workflow is established here.

Dry contact  Dry-contact interface identified; contact logic, pinout and electrical ratings are not supplied.

RS232 / CAN / RS485  Communications interfaces named in the source; protocol compatibility and wiring require separate confirmation.

COM0 / COM1  Ports named COM0/COM1. This page does not state their role, pinout or parallel-system limits.

#### Controls & indicators

Touch screen  Touch-screen display identified in the original callout.

Running status indicator  Running-status indication; source spelling is 'Runing Status'. Indicator logic is not specified.

Alarm indicator  Alarm indication identified in the source.

SOC indicator  SOC indicator identified in the source; display thresholds are not specified.

Reset control  Reset control identified by the source; operating procedure is not given on this page.

Battery switch  Battery switch identified in the source; no switching rating is given in this callout.

#### Structure & mounting

Folding handle  Mechanical folding handle; not an electrical connector.

Wall-mounted bracket  Wall-mounting bracket identified in the source; mounting load and fixing details are not supplied here.

Rollers  Rollers; the original annotation explicitly names TR8000WX and TR8500WX. Not an electrical interface.

Source: Residential ESS brochure · PDF page 3 · printed pages 5-6

---

https://ug.elvorka.com/en/products/tr-standard/

ELVORKA · eric@elvorka.com