# HP Ultra.

![HP Ultra](https://ug.elvorka.com/assets/optimized/aad85a50fc62c866-1254-q92.webp)

High-voltage battery

# HP Ultra.

A modular aluminium-alloy LFP battery stack. Six specified configurations from 8 to 48 kWh, for integration with a compatible external inverter.

INVERTER  Compatible external inverter required

ENCLOSURE  IP66 / aluminium alloy

NOMINAL ENERGY  8–48 kWh

BATTERY VOLTAGE  Confirm selected configuration

[Start your project ↗](https://ug.elvorka.com/en/#enquiry)

## Specifications

| Model / configuration | Energy (kWh) | Max. DC (kW) |
| --- | --- | --- |
| HP Ultra-8.0 | 8 | 4 |
| HP Ultra-16.0 | 16 | 8 |
| HP Ultra-24.0 | 24 | 12 |
| HP Ultra-32.0 | 32 | 16 |
| HP Ultra-40.0 | 40 | 20 |
| HP Ultra-48.0 | 48 | 24 |

System voltage and inverter compatibility must be confirmed for the chosen capacity. Floor-standing or wall-mounted installation is listed. Module additions require system review.

| Model | Dimensions (mm) | Approx. kg |
| --- | --- | --- |
| HP Ultra-8.0 | 950 × 315 × 575 / W × D × H | 75 |
| HP Ultra-16.0 | 950 × 315 × 880 / W × D × H | 130 |
| HP Ultra-24.0 | 950 × 315 × 1185 / W × D × H | 185 |
| HP Ultra-32.0 | 950 × 315 × 1490 / W × D × H | 240 |
| HP Ultra-40.0 | 950 × 315 × 1795 / W × D × H | 295 |
| HP Ultra-48.0 | 950 × 315 × 2100 / W × D × H | 350 |

Communication: CAN / RS485 / Wi-Fi / Bluetooth
Temperature: Confirm selected configuration

## Household essentials, planned for a dry dedicated equipment space.

Uganda’s rainfall patterns differ by region, with much of the country having two main rainy seasons and additional mid-year rainfall in northern and some eastern areas. Choose useful storage around your home’s tasks and a protected utility space, rather than a single national installation assumption.

Temperature:  Confirm selected configuration

ENCLOSURE  IP66 / aluminium alloy

01

### Connected household and home-office essentials

A home-office plan can start with lighting, the router and computing equipment, then add refrigeration or other selected household circuits. A dedicated dry utility room keeps the equipment accessible for service.

EU combines battery and inverter in one system for an indoor IP21 installation. Where an appropriate inverter already exists, a TR Pro 51.2 V battery offers a compact battery-only route with confirmed electrical and communication compatibility.

Which appliances should continue running, and for how many hours?

- Is this a new complete system or an extension of an existing inverter?

02

### Rain-season planning in a sheltered service area

Different rainfall seasons make the actual doorway, wall and floor exposure useful details in the inquiry. A dry service room supports an orderly installation away from household activity and water storage.

Choose the enclosure for the real position. TR Pro and HP Ultra list IP66; EU lists IP21, and standard TR/HP K offer different enclosure options. Plan shelter, fixing, drainage and protected cable routes for the exact model.

Can rain, wash water, a roof leak or standing water reach this equipment?

- Will the installation and its service access remain dry throughout local rainy periods?

03

### More energy with a compatible existing inverter

A household that already has a suitable inverter can plan a larger energy reserve around refrigeration, connectivity and chosen circuits, with capacity selected for the desired duration.

Compare compact low-voltage storage with modular high-voltage storage as distinct options. TR Pro is 51.2 V; HP Ultra requires a compatible high-voltage inverter. Check communication and current limits before choosing capacity or module count.

What are the inverter make, model and supported battery-voltage window?

- Which running and starting loads should the complete system support?

Specifications

- Plan stored energy in kWh against the required duration and average load. Check inverter AC output, battery limits and motor/compressor starting demand separately before assigning the final essential circuits.

- Use the exact battery’s environmental limits. TR Pro lists charging at 0 to 55 °C and discharging at −20 to 60 °C; EU lists charging at 0 to 55 °C and discharging at −20 to 55 °C. HP Ultra needs configuration-specific temperature confirmation.

- Treat enclosure and shelter together: an IP66 rating does not establish flood, condensation or corrosion suitability. TR standard and HP K list IP20 with IP54 optional, TB rack lists IP20, and EU lists IP21; keep their installation conditions distinct.

PRODUCT DETAIL / ORIGINAL LITERATURE

## Every side. Every connection.

Six specified 8-48kWh configurations only. Original introduction figures show an unlabeled representative stack; no underside, complete installed rear, wiring pinout or activation interface is supplied. DC poles/breaker/heatsinks and communication/parallel/GND belong to different illustrated faces. Small native drawings must not be presented as high-resolution product photography. The broader '8.0-128.0' heading is not a list of additional individually specified models.

[![DC electrical / heatsink face - original callouts](https://ug.elvorka.com/assets/product-details/hp-ultra-dc-face-callouts.png)](https://ug.elvorka.com/assets/product-details/hp-ultra-dc-face-callouts.png)

DC electrical / heatsink face - original callouts  DC-side view showing the switch, battery terminals, DC breaker and heat-dissipation plate.

[![Communication and parallel-interface face - original callouts](https://ug.elvorka.com/assets/product-details/hp-ultra-com-face-callouts.png)](https://ug.elvorka.com/assets/product-details/hp-ultra-com-face-callouts.png)

Communication and parallel-interface face - original callouts  Communication-side labels for inverter links, backup communication, BMS debugging, parallel COM1/COM2 and GND.

[![Communication-side detail (partial oblique view)](https://ug.elvorka.com/assets/product-details/hp-ultra-communication-side-detail.png)](https://ug.elvorka.com/assets/product-details/hp-ultra-communication-side-detail.png)

Communication-side detail (partial oblique view)  Oblique detail of the stack's communication-side connector area.

[![Module top / mating surfaces](https://ug.elvorka.com/assets/product-details/hp-ultra-module-top-connectors.png)](https://ug.elvorka.com/assets/product-details/hp-ultra-module-top-connectors.png)

Module top / mating surfaces  Battery module top and mating surfaces.

### Know your interfaces.

#### Power connections

Positive Pole  Positive terminal identified by the original leader line on the electrical face.

Negative Pole  Negative terminal identified by the original leader line on the electrical face.

#### Communication

Bluetooth/WIFI Antenna  Antenna label on the upper communication-side area.

Backup Com  The brochure labels this connection 'Backup Com' but does not explain its exact role.

INV CAN/RS485 Com  The INV-labelled CAN/RS485 communication connection shown in the original diagram.

Parallel COM1  First parallel-communication label near the lower part of the illustrated interface face.

Parallel COM2  Second parallel-communication label near the lower part of the illustrated interface face.

#### Controls & indicators

Switch  Switch labelled on the DC electrical-side illustration; its detailed switching function is not specified.

DC Breaker  DC breaker on the electrical / heatsink face.

Breathing Light  Light strip called out at the upper front portion in the oblique construction view.

#### Structure & mounting

Heat Dissipation Aluminum Plate  Heat-dissipation aluminum plate called out on the slim electrical-side illustration.

Wall Mounted Bracket  Mounting brackets shown on the vent-side illustration.

PDU  PDU labels the top unit in the component hierarchy; the brochure does not expand the abbreviation.

Module  Repeated battery sections below the top PDU.

Base  Base at the bottom of the illustrated stack.

BMS Debugging Interface  BMS debugging interface identified on the communication-side illustration.

Pressure Relief Valve  Pressure-relief component called out in the communication-side oblique view.

GND  Ground connection labelled GND at the bottom of the interface-side illustration.

Source: Residential ESS brochure · PDF page 5 · printed pages 9-10

---

https://ug.elvorka.com/en/products/hp-ultra/